Sign In | Join Free | My qualitytoyschina.com
China Nanjing Juge Environmental Technology Co., Ltd. logo
Nanjing Juge Environmental Technology Co., Ltd.
Serve with Heart, Create Value
Verified Supplier

1 Years

Home > Air Quality Monitoring System >

PM1.0 PM10 PM100 TSP‌ Continuous Air Quality Monitoring System For Dust Humidity Wind Speed

Nanjing Juge Environmental Technology Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

PM1.0 PM10 PM100 TSP‌ Continuous Air Quality Monitoring System For Dust Humidity Wind Speed

Brand Name : JUGE

Model Number : AG-600-Y8

Certification : IOS9001, CE

MOQ : 1 Unit

Price : USD300-5000

Payment Terms : T/T,Online order

Supply Ability : 100 Unit/Week

Delivery Time : 10-15 working days

Packaging Details : Neutral carton

Name : ‌Dust and Noise Online Monitoring System‌

Detect Gas : CO2, N2O, CH4, SF6,NF3, FREON

Range : OEM

‌Detection Principle‌ : NDIR

‌Particulate Matter (PM)‌ : PM₂.₅, PM₁₀, PM₁₀₀, TSP

Noise Monitoring : 30–130 dB(A)

‌Environmental Parameters : Temperature, Humidity, Wind Speed, Wind Direction, Atmospheric Pressure

‌Local Display‌ : 4-line display

‌Data Transmission‌ : 4G/5G/RS232/RS485

‌Power Supply‌ : AC 220V 50Hz; 150W; Protections: leakage/overload/surge

Contact Now

PM1.0 PM2.5 PM10 PM100 TSP‌ Dust Noise Humidity Wind Speed Online Monitoring System‌

>>Overview

The Dust and Noise Online Monitoring System primarily consists of a particulate matter measurement device, meteorological monitoring module, and data acquisition and wireless transmission unit. Integrated with monitoring platform software, it enables functions such as air quality publishing, comprehensive data analysis, pollution exceedance alarms, urban environment photography, video surveillance, video overlay, and mist cannon linkage.

>>Feature

Modular Design‌: Configurable with flexible combinations to customize monitoring factors as needed, suitable for large-scale grid deployment.

Self-Calibration‌: Features optically stable self-calibration and online zero-correction systems to eliminate long-term operational drift. Traceable to national standard stations.

Multi-Size Particle Monitoring‌: Measures PM₁.₀, PM₂.₅, PM₁₀, PM₁₀₀, and TSP simultaneously via metallic cutters without replacing sampling components.

Dynamic Humidity Control‌: Utilizes dynamic heating dehumidification with continuous humidity compensation to minimize environmental interference.

Robust Sampling System‌: Long-life, low-noise, anti-interference pump with adjustable sampling cycles.

Flexible Data Transmission‌: Integrated 4G/5G, RS485, and wireless units support data transfer via GPRS/CDMA, 3G/4G/5G networks, or dedicated lines. Enables 24/7/365 operation, remote parameter adjustment, and fault diagnosis.

Expandable Sensors‌: Optional modules for meteorological parameters (negative oxygen ions, rainfall, radiation, UV, etc.).

Intelligent Imaging‌: Configurable cameras with night vision and long-range capture capabilities; supports auto-snapshot, video overlay, and real-time viewing.

>>Main technical parameters
Particulate Matter (PM)
Measurement Method Laser Scattering
Measured Parameters PM₂.₅, PM₁₀, PM₁₀₀, TSP
Concentration Range PM₂.₅: 0-1000 μg/m³; PM₁₀: 0-2000 μg/m³; TSP: 0-30 mg/m³ (customizable)
Concentration Precision 0.1 µg/m³
Concentration Accuracy ±2.5% or ±10 μg/m³ (whichever is greater)
Pump Flow Rate 2.83 L/min; PID-controlled ±2.5%; Accuracy: ±2.5% F.S.
Dehumidification DHS (Dynamic Heating System) with dynamic humidity control
Particle Size Range 0.3–100 μm
Gas Path Protection Standard
Temperature Control Adjustable (10–60°C ±1°C)
Noise Monitoring
Measurement Range 30–130 dB(A)
Response Time 200 ms
Resolution 0.1 dB
Accuracy ±0.5% F.S.
Environmental Parameters
Temperature Range: -40°C to +70°C; Resolution: 0.1°C; Accuracy: ±0.2°C
Humidity Range: 0–100% RH; Resolution: 0.1% RH; Accuracy: ±3% RH
Wind Speed Range: 0–60 m/s; Resolution: 0.1 m/s; Accuracy: ±(0.3 + 0.03V) m/s
Wind Direction Range: 0–360°; Resolution: 1°; Accuracy: ±3°
Atmospheric Pressure Range: 45–120 kPa; Resolution: 0.01 kPa; Accuracy: ±0.05 kPa (25°C @ 103.5 kPa)
Local Display 4-line display; Switch power supply; RS485 interface; Dimensions: 1020×540×120 mm
Mounting Setup 3m national-standard pole (or bracket); Lightning rod (Ø89 mm, 2 mm thickness, two 1.5m threaded rods). Wall-mount optional.
Data Transmission 4G/5G/RS232/RS485; Compliant with Chinese national standard HJ 212-2017
Power Supply AC 220V 50Hz; 150W; Protections: leakage/overload/surge
Operating Environment Temperature: -40°C to +70°C; Humidity: 0–95% RH (non-condensing); IP53 rating
Host Functions
Data Capture Rate ≥90% for particulate data
Local Storage ≥24 months of historical data
Data Recovery Auto-recovery and retransmission upon network restoration
Linkage System Supports mist cannon and spray linkage
Remote Management Remote firmware updates, parameter configuration, linkage control, and diagnostics


Product Tags:

PM100 Air Quality Monitoring System

      

PM10 Air Quality Monitoring System

      

PM1.0 continuous air monitoring system

      
Quality PM1.0 PM10 PM100 TSP‌ Continuous Air Quality Monitoring System For Dust Humidity Wind Speed wholesale

PM1.0 PM10 PM100 TSP‌ Continuous Air Quality Monitoring System For Dust Humidity Wind Speed Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Nanjing Juge Environmental Technology Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)